Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Arq. bras. oftalmol ; 84(3): 214-219, May-June 2021. graf
Article in English | LILACS | ID: biblio-1248961

ABSTRACT

ABSTRACT Purpose: To evaluate the influence of pupil dynamics on the defocus profile and area-of-focus of eyes implanted with a diffractive multifocal intraocular lens (IOL). Methods: This prospective randomized trial was conducted at the Department of Ophthalmology, School of Medicine of Ribeirão Preto, University of São Paulo, Brazil. Thirty-eight patients were randomly assigned to receive the multifocal SN6AD1 (n=20) or the aspheric monofocal SN60WF (aIOL) (n=18) IOLs bilaterally. Dynamic pupillometry, visual acuity for distance and near, corrected and uncorrected, and a defocus profile were assessed postoperatively. The area-of-focus was calculated using an empirical polynomial model of the defocus profile. Results: Sixteen patients (32 eyes) in the multifocal SN6AD1 group and 17 patients (34 eyes) in the aspheric monofocal SN60WF group completed the 1-year follow-up. There were no significant between-group differences in monocular uncorrected distance or near visual acuity. The defocus profiles of the mfIOL group showed a double peak, whereas those of the aspheric monofocal SN60WF group showed only one peak, which is typical for a monofocal intraocular lens. The area-of-focus of the aIOL group (4.66 ± 1.51 logMARxD) was significantly different from that of the multifocal SN6AD1 (1.99 ± 1.31 logMARxD). Pupil size at maximum contraction after exposure to a flash of 30 cd/m2 for 1 second was significantly correlated with a better area-of-focus in the multifocal SN6AD1 group (r=0.54; p=0.0017), whereas this was not the case in the aspheric monofocal SN60WF group. Conclusion: These findings indicate that in eyes implanted with an multifocal SN6AD1, the smaller the pupil size, the better is the area-of-focus and hence the better is the visual performance. This correlation was not found for the aspheric monofocal SN60WF.(AU)


RESUMO Objetivo: Avaliar a influência da dinâmica pupilar na curva de desfoco de olhos implantados com lente intraoculares multifocais difrativas. Métodos: Estudo prospectivo e randomizado realizado na Faculdade de Medicina de Ribeirão Preto - Universidade de São Paulo - Departamento de Oftalmologia. Trinta e oito pacientes foram aleatoriamente designados para receber bilateralmente lentes intraoculares SN6AD1 (n=20) (mfIOL) ou SN60WF (n=18) (aIOL). Além da acuidade visual para longe e perto, corrigida e não corrigida, e curva de desfoco, foi ainda realizada pupilometria dinâmica. A área sob a curva de desfoco foi calculada usando um modelo polinomial empírico. Resultados: Um total de 16 e 17 pacientes (n=32 e 34 olhos) completaram 1 ano de seguimento nos grupos mfIOL e aIOL, respectivamente. Não houve diferenças significativas entre grupos para as acuidades visuais seja para longe ou perto. As curvas de desfoco do grupo mfIOL mostraram um pico duplo; enquanto o SN60WF mostrou apenas um pico, típico para uma lente intraoculares monofocal. A média da área sob a curva de desfoco do grupo aIOL foi (4,66 ± 1,51 logMAR.dp), e essa é estatisticamente significante diferente da métrica do grupo mfIOL (1,99 ± 1,31 logMAR.dp). A pupila na contração máxima após a exposição a um flash de 30 cd/m2 por 1 segundo foi significativamente correlacionada com uma melhor área de foco no grupo mfIOL (r=0,54; p=0,0017), essa relação não foi observada para o grupo aIOL. Conclusão: Estes dados indicam que quanto menor a pupila durante contração, melhor é a área sob a curva de desfoco e, portanto, o desempenho visual dos olhos implantados com essa mfIOL. Esta correlação não foi encontrada para lentes intraoculares monofocais.(AU)


Subject(s)
Humans , Cataract Extraction , Pupil/physiology , Phacoemulsification/instrumentation , Multifocal Intraocular Lenses , Prospective Studies
2.
Rev. bras. oftalmol ; 79(5): 344-347, set.-out. 2020. graf
Article in Portuguese | LILACS | ID: biblio-1137992

ABSTRACT

Resumo A cirurgia de catarata com implante de lente intra-ocular é uma das cirurgias mais realizadas no mundo e, atualmente, os pacientes que se submetem a essa cirurgia podem utilizar o implante com lente intraocular (LIO) multifocal como alternativa ao uso de óculos. Um grande desafio para o cirurgião são os pacientes já submetidos previamente a ceratotomia radial (RK), pois além de terem um cálculo biométrico mais desafiador, apresentam importantes aberrações ópticas corneanas, sendo uma contra-indicação para o uso de lentes multifocais para a maioria dos oftalmologistas. Neste artigo, relatamos o caso de uma paciente que foi submetida, na juventude, a uma RK e passou a referir importante incômodo visual após a correção de catarata com facectomia e implante de LIO multifocal. Esta paciente foi submetida a uma ceratectomia fotorrefrativa (PRK) para diminuir as irregularidades da córnea com boa evolução clínica e resultado visual satisfatório. Esse caso chama a atenção para a alternativa do excimer laser topoguiado em casos semelhantes e alerta para o risco do uso desse tipo de lente em córneas irregulares.


Abstract Cataract surgery with intraocular lens implantation is one of the most commonly performed surgeries in the world and, currently, patients who undergo this surgery can use the multifocal intraocular lens (IOL) implant as an alternative to wearing glasses. A great challenge for the surgeon are patients who have previously undergone radial keratotomy (RK), because in addition to having a more challenging biometric calculation, they also have important corneal optical aberrations, being a contraindication for the use of multifocal lenses for most patients. ophthalmologists. In this article, we report the case of a patient who underwent a RK in her youth and started to report an important visual discomfort after cataract correction with facectomy and multifocal IOL implantation. This patient underwent a photorefractive keratectomy (PRK) to reduce corneal irregularities with good clinical evolution and satisfactory visual result. This case draws attention to the alternative of topography-guided laser excimer in similar cases and warns of the risk of using this type of lens in irregular corneas.


Subject(s)
Humans , Female , Middle Aged , Keratotomy, Radial , Eye Abnormalities/surgery , Photorefractive Keratectomy , Refractive Surgical Procedures , Lasers, Excimer/therapeutic use , Multifocal Intraocular Lenses
3.
Arq. bras. oftalmol ; 83(2): 141-145, Mar.-Apr. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088976

ABSTRACT

ABSTRACT Purpose: To compare the postoperative refractive predictability of IOLMaster 500 and Pentacam HR on the basis of keratometry and anterior chamber depth values in eyes with an indication for multifocal intraocular lens (IOL) implantation. Methods: This was a retrospective study conducted on 118 eyes treated with phacoemulsification and multifocal intraocular lens implantation. Only the eyes that achieved emmetropia in the dynamic refraction performed on postoperative day 30 were included. Haigis' formula was used in each case to calculate the intraocular lens power, and the intraocular lens with the target refraction closest to emmetropia was implanted. Four lens calculation scenarios were tested by combining keratometry and anterior chamber depth measurements obtained using the two devices. Results: IOLMaster 500 and Pentacam HR differed with regard to mean keratometry (D 0.07 ± 0.03 D; p=0.0065) and anterior chamber depth (D 0.08 ± 0.01 mm; p<0.001). In the analysis of covariance, the following differences were obtained using the Haigis' formula when confronted with the biometric values obtained by inserting keratometry and anterior chamber depth values, respectively: Penta/IOL x IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/Penta × IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/IOL × IOL/IOL (0.11 ± 0.03; p=0.001); Penta/Penta × IOL/IOL (0.11 ± 0.03; p=0.002); IOL/IOL × IOL/Penta (0.02 ± 0.03; p=0.865); and Penta/IOL × Penta/Penta (0.002 ± 0.03; p=0.99). The difference was smaller when measuring the anterior chamber depth using the IOLMaster 500, regardless of which device was used to measure keratometry. Conclusions: Pentacam HR significantly differed from IOLMaster 500 when calculating keratometry. As regards the anterior chamber depth, the two devices were equally accurate.


RESUMO Objetivo: Comparar a previsibilidade refrativa pós-operatória do IOLMaster 500 e Pentacam HR com base nos valores de ceratometria e profundidade de câmara anterior nos olhos com indicação de implante de lentes intraoculares multifocais. Métodos: Estudo retrospectivo realizado em 118 olhos tratados com facoemulsificação e implante de lentes intraoculares multifocal. Apenas os olhos que atingiram a emetropia na refração dinâmica no 30º dia pós-operatório foram incluídos. A fórmula de Haigis foi usada em cada caso para calcular o poder das lentes intraoculares, e a lente intraocular com a refração alvo mais próxima da emetropia foi implantada. Cenários de cálculo de quatro lentes foram testados pela combinação de medidas de ceratometria e profundidade de câmara anterior obtidas usando os dois dispositivos. Resultados: IOLMaster 500 e Pentacam HR diferiram quanto à média de ceratometria (D 0,07 ± 0,03 D; p=0,0065) e profundidade de câmara anterior (D 0,08 ± 0,01 mm; p<0,001). Na análise da covariância, as seguintes diferenças foram obtidas usando a fórmula de Haigis quando confrontadas com os valores biométricos obtidos pela inserção dos valores de ceratometria e profundidade de câmara anterior, respectivamente: Penta/IOL x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/Penta x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/IOL x IOL/IOL (0,11 ± 0,03; p=0,001); Penta/Penta x IOL/IOL (0,11 ± 0,03; p=0,002); IOL/IOL x IOL/Penta (0,02 ± 0,03; p=0,865); Penta/IOL x Penta/Penta (0,002 ± 0,03; p=0,99). A diferença foi menor ao medir a profundidade da câmara anterior usando o IOLMaster 500, independentemente de qual dispositivo foi usado para medir a ceratometria. Conclusões: O Pentacam HR diferiu significativamente do IOLMaster 500 no cálculo de ceratometria. Quanto à profundidade da câmara anterior, os dois dispositivos foram igualmente precisos.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Phacoemulsification/methods , Cornea/pathology , Corneal Topography/instrumentation , Lens Implantation, Intraocular/methods , Multifocal Intraocular Lenses , Anterior Chamber/pathology , Postoperative Period , Reference Values , Refraction, Ocular/physiology , Time Factors , Visual Acuity/physiology , Predictive Value of Tests , Retrospective Studies , Biometry , Treatment Outcome , Cornea/diagnostic imaging , Interferometry/instrumentation , Interferometry/methods , Anterior Chamber/diagnostic imaging
4.
Rev. bras. oftalmol ; 77(5): 268-271, set.-out. 2018. graf
Article in Portuguese | LILACS | ID: biblio-977865

ABSTRACT

Resumo Objetivos: Medir o ângulo lâmbda (AL) em indivíduos no pré-operatório de facectomias, correlacionando a sua presença com o comprimento axial e o esférico dos olhos. Sugerir condutas para o implante de LIO multifocal de acordo com a presença do ângulo lâmbda. Métodos: Estudo transversal em 128 olhos de 74 indivíduos candidatos à cirurgia de catarata para registrar a equivalente presença do ângulo lâmbda. Resultados: Avaliando o ângulo lâmbda observou-se uma correlação positiva (r= 0,559 / p= 0,000) para o tamanho desse ângulo comparando-se os dois olhos. Não houve correlação entre o tamanho do ângulo lâmbda e o equivalente esférico no olho direito (r= -0,027 / p= 0,840), mas foi verificada correlação positiva para o olho esquerdo (r= 0,313 / p= 0,013). A presença da hipermetropia correlacionou com os comprimentos axiais pequenos, assim como a miopia com os grandes. Observou-se correlação negativa entre o tamanho do ângulo lâmbda e o comprimento axial para os dois olhos, sendo de r= -0,249 para o olho direito (p= 0,042) e r= -0,281 para o olho esquerdo (p= 0,018) Conclusões: Houve correlação entre a presença de ângulo lâmbda maior e comprimentos axiais menores para os dois olhos. Para o equivalente esférico hipermétrope houve correlação com a presença de um ângulo lâmbda maior apenas para o olho esquerdo. Esse trabalho sugere parcimônia nos implantes de LIO multifocal na presença de ângulo lâmbda significativo, baseado na teoria que a presença desse ângulo é reguladora do equilíbrio entre as aberrações da superfície corneana versus cristalineanas.


Abstract Objectives: To measure the labral angle (LA) in individuals in the preoperative period of facectomies, correlating their presence with axial length and spherical equivalent of the eyes. Suggest conduits for the implantation of multifocal IOL according to the presence of the lambda angle. Methods: A cross-sectional study of 128 eyes of 74 individuals who were candidates for cataract surgery to record the presence of the lambda angle. Results: A positive correlation (r = 0.559 / p = 0.000) was observed for the angle of this angle by comparing the two eyes. There was no correlation between the size of the lambda angle and the spherical equivalent in the right eye (r = -0.027 / p = 0.840), but a positive correlation was observed for the left eye (r = 0.313 / p = 0.013). The presence of hyperopia correlated with small axial lengths, as did myopia with large ones. There was a negative correlation between the angle of the tongue and the axial length of the two eyes, with r = -0.249 for the right eye (p = 0.042) and = 0.281 for the left eye (p = 0.018). Conclusions: There was a correlation between the presence of a larger lambda angle and smaller axial lengths for both eyes. For the spherical hypermétrope equivalent, there was a correlation with the presence of a larger blunt angle only for the left eye. This work suggests parsimony in multifocal IOL implants in the presence of a significant lamella angle, based on the theory that the presence of this angle regulates the balance between corneal versus crystaline surface aberrations.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Pupil/physiology , Corneal Topography/methods , Lens Implantation, Intraocular , Axial Length, Eye , Multifocal Intraocular Lenses , Lighting , Cataract Extraction/statistics & numerical data , Cross-Sectional Studies , Biometry/instrumentation , Biometry/methods , Preoperative Period , Fixation, Ocular , Ocular Physiological Phenomena
SELECTION OF CITATIONS
SEARCH DETAIL